Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1768493.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $14,895.00
Current Penalty: $8,937.00
Issuance Date: 01/22/2025
Nr Instances: 1
Nr Exposed: 125
Abatement Date: 02/18/2025
Gravity: 10
Report ID: 0728500
Contest Date:
Final Order: 02/18/2025
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/18/2025 | $8,937.00 | 02/18/2025 | Serious | |
Penalty | Z: Issued | 01/22/2025 | $14,895.00 | 02/18/2025 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: At the worksite located at 1000 Schifferdecker Avenue, Joplin MO: Employees were exposed to struck by and caught in hazards. The employer did not develop machine specific procedures for the control of hazardous energy for the MVP sprayer and pump.