Violation Detail
Standard Cited: 19100147 C04 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1767969.015
Citation: 01002
Citation Type: Serious
Abatement Date: 03/04/2025 2
Initial Penalty: $15,606.00
Current Penalty: $15,606.00
Issuance Date: 02/03/2025
Nr Instances: 1
Nr Exposed: 5
Related Event Code (REC):
Gravity: 5
Report ID: 0830600
Contest Date:
Final Order: 02/27/2025
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 02/03/2025 | $15,606.00 | 03/04/2025 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section: (a) Rail Mill, North stamp wheel: On or about August 9, 2024, and at times prior, the employer did not ensure that energy control procedures included the specific procedural steps for the placement and removal of lockout devices, and specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices. This condition exposed employees to caught-between and crushed-by hazards.