Violation Detail
Standard Cited: 19260451 G04 XV General requirements.
Inspection Nr: 1764905.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $3,803.00
Current Penalty: $3,803.00
Issuance Date: 10/17/2024
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 5
Report ID: 0214500
Contest Date:
Final Order: 11/13/2024
Related Event Code (REC): I
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 10/17/2024 | $3,803.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.451(g)(4)(xv): Crossbracing is acceptable in place of a midrail when the crossing point of two braces is between 20 inches (0.5 m) and 30 inches (0.8 m) above the work platform or as a toprail when the crossing point of two braces is between 38 inches (0.97 m) and 48 inches (1.3 m) above the work platform. The end points at each upright shall be no more than 48 inches (1.3 m) apart. a)At or near 474 Hudson Terrace, Englewood Cliffs - Exterior Frame Scaffold - Stairtower: employees engaged in masonry work from a frame scaffold platform without proper railing were exposed to fall hazards of approximately 42 feet, on or about 7/29/24.