Violation Detail
Standard Cited: 19100179 N03 I Overhead and gantry cranes.
Inspection Nr: 1763552.015
Citation: 01002
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $16,131.00
Current Penalty: $9,600.00
Issuance Date: 09/26/2024
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 10/31/2024
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 10/24/2024
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/24/2024 | $9,600.00 | 10/31/2024 | Other | |
Penalty | Z: Issued | 09/26/2024 | $16,131.00 | 10/31/2024 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.179(n) Handling the load: (3) Moving the load: (i): The load shall be well secured and properly balanced in the sling or lifting device before it is lifted more than a few inches. a) On or about July 22, 2024, the employer failed to ensure that a 38 metric-ton manufactured module was properly secured before lifting it with a 60-ton ENERP AC gantry crane. Prior to conducting a secondary lift of the module to center the module on a trailer, a shackle was inadvertently removed and not properly communicated to the crane operator. This resulted m the load shifting during the initial lifting process resulting m the gantry crane tipping forward.