Violation Detail
Standard Cited: 19260651 J02 Specific Excavation Requirements.
Inspection Nr: 1755861.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,148.00
Current Penalty: $2,304.00
Issuance Date: 09/26/2024
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 5
Report ID: 0522300
Contest Date:
Final Order: 10/20/2024
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/20/2024 | $2,304.00 | Serious | ||
| Penalty | Z: Issued | 09/26/2024 | $4,148.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.651(j)(2):Employees were not protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations, or by a combination of both if necessary: On or about June 17, 2024, the employer did not ensure that soil spoil piles from the excavation were more than 2 feet from the excavation in which employees were observed working. At the time of inspection the soil pile was placed directly next to and near the edge of the excavation.