Violation Detail
Standard Cited: 19100134 F02 Respiratory Protection.
This violation item has been deleted.
Inspection Nr: 1750702.015
Citation: 01002
Citation Type: Serious
Abatement Status:
Initial Penalty: $11,292.00
Current Penalty: $0.00
Issuance Date: 10/21/2024
Nr Instances: 1
Nr Exposed: 75
Abatement Date: 12/09/2024
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 11/25/2024
Related Event Code (REC): C
Emphasis:
Substance: 0020
Substance: 1060
Substance: 1470
Substance: 1660
Substance: 1860
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/25/2024 | $0.00 | 12/09/2024 | Serious | |
Penalty | Z: Issued | 10/21/2024 | $11,292.00 | 12/09/2024 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.134(f)(2): Fit Testing. The employer shall ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter. (a) On or about May 28, 2024, the employer did not ensure that each employee who wore a respirator with a tight fitting facepiece was fit tested before performing a job task where respirator use was required.