Violation Detail
Standard Cited: 19261053 B01 Ladders.
Inspection Nr: 1744891.015
Citation: 01002
Citation Type: Serious
Abatement Status: Not Completed - AD Discretion
Initial Penalty: $5,323.00
Current Penalty: $5,323.00
Issuance Date: 05/28/2024
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 05/31/2024
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 07/05/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 05/28/2024 | $5,323.00 | 05/31/2024 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: On or about April 30, 2024 the employer Marlin Beachy Jr. DBA JR's Roofing at jobsite located at 2422 Torino Dr. Port Clinton OH 43452, did not ensure the side rails of one fiberglass extension ladder was extended at least three feet above the landing surface. Two employees were exposed to falls from approximately 19 feet or greater from the top of the second (roof) level to the ground below while using a Werner brand fiberglass extension ladder to access the second (roof) level to perform residential roofing activities on a single family home.