Violation Detail
Standard Cited: 19100219 C03 Mechanical power-transmission apparatus.
Inspection Nr: 1736198.015
Citation: 01002
Citation Type: Other
Abatement Status: Corrected During Inspection
Initial Penalty: $9,218.00
Current Penalty: $7,895.85
Issuance Date: 07/12/2024
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 08/09/2024
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/09/2024 | $7,895.85 | Other | ||
| Penalty | Z: Issued | 07/12/2024 | $9,218.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.219(c)(3): Guarding vertical and inclined shafting. Vertical and inclined shafting seven (7) feet or less from floor or working platform, excepting maintenance runways, shall be enclosed with a stationary casing in accordance with requirements of paragraphs (m) and (o) of this section. On or about March 17, 2024, at a facility located at 718 High Street in New London, Wisconsin, employees were not provided machine guarding to protect operators and other employees in the flexo press department near flexo-press #8 on the white ink barrel spinning vertical shafting.