Violation Detail
Standard Cited: 19100147 E02 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1716756.015
Citation: 01002
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $11,524.00
Current Penalty: $7,500.00
Issuance Date: 05/24/2024
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 07/26/2024
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 06/24/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/24/2024 | $7,500.00 | 07/26/2024 | Other | |
Penalty | Z: Issued | 05/24/2024 | $11,524.00 | 06/25/2024 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(e)(2)(i): The work area shall be checked to ensure that all employees have been safely positioned or removed. On or about February 16, 2024, at the facility located at 3805 North Freedom Road, Appleton, Wisconsin; an employee was exposed to machine hazards associated with moving parts while assisting another employee in sanitation on Molder #3. The one employee was exposed to hazardous machine movement while assisting, and the other employee was using the controls to move the ram. The employer did not ensure that employees implemented energy control application steps or equivalent protective measures prior to allowing them to sanitize the equipment. The machine was not deenergized prior to the employee engaging in servicing/maintenance activity. As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.