Violation Detail
Standard Cited: 19260651 K01 Specific Excavation Requirements.
This violation item has been deleted.
Inspection Nr: 1708399.015
Citation: 01002
Citation Type: Serious
Abatement Status:
Initial Penalty: $6,453.00
Current Penalty: $0.00
Issuance Date: 04/03/2024
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 05/01/2024
Gravity: 5
Report ID: 0830600
Contest Date:
Final Order: 04/29/2024
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/29/2024 | $0.00 | 05/01/2024 | Serious | |
| Penalty | Z: Issued | 04/03/2024 | $6,453.00 | 05/01/2024 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions: a) On or about November 3, 2023, the exposing employer, Ovation Plumbing, Inc., did not ensure an inspection of an excavation was made by a competent person for evidence of a hazardous situation that could have resulted in a soil collapse of the excavation walls. By not doing so, employees who were required to engage in sewer line repairs inside of an excavation were exposed to struck-by and crushing hazards.
Translate