Violation Detail
Standard Cited: 19100124 I02
Inspection Nr: 1698341.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $16,131.00
Current Penalty: $16,131.00
Issuance Date: 01/29/2024
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 10
Report ID: 0111700
Contest Date:
Final Order: 02/26/2024
Related Event Code (REC): A
Emphasis:
Substance: 1860
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 01/29/2024 | $16,131.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.124(i)(2): An employee was permitted to clean the interior of the dip tank before pockets where hazardous vapors may have accumulated were ventilated and cleared:(a) Location: Automated Plating Line, Brite Dip Tank On or about, September 15, 2023, an employee entered the Brite Dip tank on the automated plating line when it had not been ventilated to remove nitric acid and nitric oxide vapors.