Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1697621.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $15,625.00
Current Penalty: $14,062.50
Issuance Date: 12/05/2023
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 10
Report ID: 0111100
Contest Date:
Final Order: 02/02/2024
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/02/2024 | $14,062.50 | Serious | ||
| Penalty | Z: Issued | 12/05/2023 | $15,625.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(d)(2):The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: Establishment - Employer failed to ensure the robotic stacking arm was shut down per lockout tagout procedures prior to performing maintenance work on the conveyor system.