Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1693193.015
Citation: 01002
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $15,625.00
Current Penalty: $0.00
Issuance Date: 12/05/2023
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 01/24/2024
Gravity: 10
Report ID: 0134000
Contest Date:
Final Order: 01/03/2024
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/03/2024 | $0.00 | 01/24/2024 | Other | |
Penalty | Z: Issued | 12/05/2023 | $15,625.00 | 01/24/2024 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(7)(i) - The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: Location - Production Area On or about 8/24/23, an employee entered the caged area of the PEER machine to clear a jammed drawer without appropriate level of training.