Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1688814.015
Citation: 01002
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $14,518.00
Current Penalty: $14,518.00
Issuance Date: 02/01/2024
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 06/17/2025
Gravity: 10
Report ID: 0418800
Contest Date: 02/26/2024
Final Order: 05/05/2025
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 05/05/2025 | $14,518.00 | 06/17/2025 | Other | |
Penalty | C: Contested | 02/28/2024 | $14,518.00 | 03/20/2024 | Serious | |
Penalty | Z: Issued | 02/01/2024 | $14,518.00 | 03/20/2024 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. a) On or about August 4, 2023, at 2600 Eisenhower Blvd., Fort Lauderdale, FL 33316, South Cross Screw area, employees were exposed to amputation and electrical hazards, in that the employer did not ensure that periodic inspections of the energy control procedure(s) for the South Cross Screw were performed to prevent accidental contact with nip points, rotating parts, and electrically energized parts.