Violation Detail
Standard Cited: 19260651 C02 Specific Excavation Requirements.
Inspection Nr: 1686403.015
Citation: 01002
Citation Type: Serious
Abatement Status: Not Completed - Worksite Changed
Initial Penalty: $10,938.00
Current Penalty: $10,938.00
Issuance Date: 12/06/2023
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 01/03/2024
Gravity: 10
Report ID: 0626300
Contest Date:
Final Order: 01/12/2024
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 12/06/2023 | $10,938.00 | 01/03/2024 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: (a) On or about July 26, 2023 and July 27, 2023 there was no safe means of egress for employees.