Violation Detail
Standard Cited: 19100272 G01 II Grain handling facilities.
Inspection Nr: 1681877.015
Citation: 01002
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $4,688.00
Current Penalty: $4,688.00
Issuance Date: 12/29/2023
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 02/16/2024
Gravity: 10
Report ID: 0626000
Contest Date:
Final Order: 05/16/2024
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/16/2024 | $4,688.00 | 02/16/2024 | Other | |
Penalty | Z: Issued | 12/29/2023 | $4,688.00 | 02/16/2024 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.272(g)(1)(ii): All mechanical, electrical, hydraulic, and pneumatic equipment which presents a danger to employees inside grain storage structures shall be deenergized and shall be disconnected, locked-out and tagged, blocked-off, or otherwise prevented from operating by other equally effective means or methods. On or about July 4, 2023, and at times prior thereto at 106 FM 796 TYNAN, TX employees conducted grain handling facility repairs at this workplace such as but not limited to removing and replacing motor pulley belts did not implement procedures for the use of tags and locks which would prevent the inadvertent application of energy or motion to the equipment being serviced or repaired.