Violation Detail
Standard Cited: 19100179 L03 III D Overhead and gantry cranes.
Inspection Nr: 1675828.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,844.00
Current Penalty: $3,507.00
Issuance Date: 09/19/2023
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 11/06/2023
Gravity: 5
Report ID: 0523400
Contest Date:
Final Order: 10/13/2023
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/13/2023 | $3,507.00 | 11/06/2023 | Serious | |
| Penalty | Z: Issued | 09/19/2023 | $5,844.00 | 11/06/2023 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.179(l)(3)(iii)(d):Pendant control stations shall be kept clean and function labels kept legible. (a) On or about June 8, 2023, a Budgit, 2 ton, overhead hoist located over NP 7-10 Die Cast, had a remote operated pendant control that was not legible for employees to identify the functions of the buttons, thereby exposing employees to a struck-by hazard.
Translate