Violation Detail
Standard Cited: 19100147 C04 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1666020.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,813.00
Current Penalty: $4,687.80
Issuance Date: 10/20/2023
Nr Instances: 3
Nr Exposed: 4
Abatement Date: 11/16/2023
Gravity: 5
Report ID: 0215800
Contest Date:
Final Order: 11/11/2023
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/11/2023 | $4,687.80 | 11/16/2023 | Serious | |
| Penalty | Z: Issued | 10/20/2023 | $7,813.00 | 11/16/2023 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(4)(ii): The lockout/tagout procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance. a) Production area, Stamped Fittings, Inc., 217 Lenox Ave., Elmira Heights, NY 14903, Omera Gasket Machine 1, on or about 4/26/2023. The written lockout/tagout procedures were not adequate for the Omera Gasket Machines, in that they did not clearly and specifically outline the specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. Procedures did not include the control of all energy sources, including, but not limited to, pneumatic and hydraulic sources of energy. b) Production area, Stamped Fittings, Inc., 217 Lenox Ave., Elmira Heights, NY 14903, Omera Gasket Machine 2, on or about 4/26/2023. The written lockout/tagout procedures were not adequate for the Omera Gasket Machines, in that they did not clearly and specifically outline the specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. Procedures did not include the control of all energy sources, including, but not limited to, pneumatic and hydraulic sources of energy. c)Production area, Stamped Fittings, Inc., 217 Lenox Ave., Elmira Heights, NY 14903, Omera Gasket Machine 3, on or about 4/26/2023. The written lockout/tagout procedures were not adequate for the Omera Gasket Machines, in that they did not clearly and specifically outline the specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. Procedures did not include the control of all energy sources, including, but not limited to, pneumatic and hydraulic sources of energy.
Translate