Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1658586.015
Citation: 01002
Citation Type: Other
Abatement Status: Corrected During Inspection
Initial Penalty: $14,063.00
Current Penalty: $7,031.00
Issuance Date: 09/20/2023
Nr Instances: 1
Nr Exposed: 6
Abatement Date:
Gravity: 10
Report ID: 0214500
Contest Date: 10/16/2023
Final Order: 05/17/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 05/17/2024 | $7,031.00 | Other | ||
Penalty | C: Contested | 10/24/2023 | $14,063.00 | Serious | ||
Penalty | Z: Issued | 09/20/2023 | $14,063.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Catbridge Coater / Laminator (Coater #5) Serial Number PL55766: The employer did not establish energy control procedures for servicing and maintenance of the Catbridge Coater/Laminator, including, but not limited to, repair of a web break in the accumulator section, on or about 3/23/23.