Violation Detail
Standard Cited: 19260451 B01 I General requirements.
Inspection Nr: 1655630.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,688.00
Current Penalty: $2,344.00
Issuance Date: 08/03/2023
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 10
Report ID: 0418800
Contest Date:
Final Order: 08/28/2023
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/28/2023 | $2,344.00 | Serious | ||
| Penalty | Z: Issued | 08/03/2023 | $4,688.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary: On or about 03/06/2023 at the job site located at 100 Blue Sky Circle, Fort Pierce, FL, 34981, scaffold platforms were not fully planked, exposing employees to a 5-foot and 25-foot fall hazard to a lower level.