Violation Detail
Standard Cited: 19100095 G01 Occupational noise exposure.
Inspection Nr: 1648021.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $10,938.00
Current Penalty: $6,010.00
Issuance Date: 07/06/2023
Nr Instances: 5
Nr Exposed: 5
Abatement Date: 08/01/2023
Gravity: 10
Report ID: 0213900
Contest Date:
Final Order: 09/06/2023
Related Event Code (REC): R
Emphasis:
Substance: 8110
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/06/2023 | $6,010.00 | 08/01/2023 | Serious | |
| Penalty | Z: Issued | 07/06/2023 | $10,938.00 | 08/01/2023 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.95(g)(1): The employer did not establish and maintain an audiometric testing program by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels: a) Build Room: A Builder was exposed to continuous noise levels in excess of the allowable 8-hour time-weighted average sound level. The employee's dosimeter dBA level was 253.2% of the permissible level (90 dBA) and was equivalent to approximately 96.7 dBA. The sampling was performed for 463 minutes during one shift on 5/3/2023. Zero exposure was assumed for the unsampled period of time. b) Build Room: A Builder was exposed to continuous noise levels in excess of the allowable 8-hour time-weighted average sound level. The employee's dosimeter dBA level was 316.5% of the permissible level (90 dBA) and was equivalent to approximately 98.3 dBA. The sampling was performed for 343 minutes during one shift on 5/3/2023. Zero exposure was assumed for the unsampled period of time. c) Build Room: A Builder was exposed to continuous noise levels in excess of the allowable 8-hour time-weighted average sound level. The employee's dosimeter dBA level was 139.1% of the permissible level (90 dBA) and was equivalent to approximately 92.4 dBA. The sampling was performed for 396 minutes during one shift on 5/3/2023. Zero exposure was assumed for the unsampled period of time. d) Saw Room: A Dismantler was exposed to continuous noise levels in excess of the allowable 8-hour time-weighted average sound level (Action Level). The employee's dosimeter dBA level was 259.8% of the permissible level (90 dBA) and was equivalent to approximately 96.9 dBA. The sampling was performed for 464 minutes during one shift on 5/3/2023. Zero exposure was assumed for the unsampled period of time. e) Saw Room: A Dismantler was exposed to continuous noise levels in excess of the allowable 8-hour time-weighted average sound level. The employee's dosimeter dBA level was 225.9% of the permissible level (90 dBA) and was equivalent to approximately 97.3 dBA. The sampling was performed for 395 minutes during one shift on 5/3/2023. Zero exposure was assumed for the unsampled period of time. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Translate