Violation Detail
Standard Cited: 19100179 J02 VI Overhead and gantry cranes.
Inspection Nr: 1647222.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,376.00
Current Penalty: $6,563.20
Issuance Date: 06/21/2023
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 07/18/2023
Gravity: 5
Report ID: 0626700
Contest Date:
Final Order: 09/14/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/14/2023 | $6,563.20 | 07/18/2023 | Serious | |
Penalty | Z: Issued | 06/21/2023 | $9,376.00 | 07/18/2023 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.179(j)(2)(vi): The following items shall be inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections. All deficiencies such as listed shall be carefully examined and determination made as to whether they constitute a safety hazard: All functional operating mechanisms for excessive wear of components. a) At the worksite in Bay #4, the KCI 2-ton crane, was observed to have a safety latch that was inoperable on the crane hook exposing employees to a struck by hazard.