Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1639749.015
Citation: 01002
Citation Type: Serious
Abatement Status:
Initial Penalty: $15,625.00
Current Penalty: $0.00
Issuance Date: 05/08/2023
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 06/09/2023
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 08/14/2023
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/14/2023 | $0.00 | 06/09/2023 | Serious | |
Penalty | Z: Issued | 05/08/2023 | $15,625.00 | 06/09/2023 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(6)(i):The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. a) On or before 12/14/2022 the employer did not conduct periodic inspection of the energy control procedures annually, for equipment such as but not limited to; the procedures for the Rosenthal Shearer-2 (model # WAS-6 HHUJEA) to ensure that deviations such as testing and removal of lockout devices were included in the procedures, showing the annual inspections were conducted.