Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1629890.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $15,625.00
Current Penalty: $15,625.00
Issuance Date: 04/05/2023
Nr Instances: 2
Nr Exposed: 6
Abatement Date: 05/01/2023
Gravity: 10
Report ID: 0830100
Contest Date:
Final Order: 04/20/2023
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/20/2023 | $15,625.00 | 05/01/2023 | Serious | |
Penalty | Z: Issued | 04/05/2023 | $15,625.00 | 05/01/2023 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) Boiler #1 Spreader #3: On or about October 08, 2022, and at times prior, employees were exposed to crushing hazards from the unexpected machine startup while clearing a coal jam without the protection of lockout or tagout devices to control stored hazardous energies such as, but not limited to, electrical and mechanical. b) Boiler #1 Spreader #3: On or about October 09, 2022, and at times prior, employees were exposed to crushing hazards from then unexpected machine startup while clearing a coal jam without the protection of lockout or tagout devices to control stored hazardous energies such as, but not limited to, electrical and mechanical.