Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1629699.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $14,063.00
Current Penalty: $7,031.50
Issuance Date: 03/06/2023
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 07/03/2023
Gravity: 10
Report ID: 0521400
Contest Date:
Final Order: 04/03/2023
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/03/2023 | $7,031.50 | 07/03/2023 | Serious | |
| Penalty | Z: Issued | 03/06/2023 | $14,063.00 | 04/03/2023 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): a) On or about October 14, 2022, the employer did not ensure that a heading operator employee implemented energy control application steps prior to allowing them to make adjustments within the tooling area of Header #21, 3/16 National Single Die Tubular Rivet Header, SN36998. The machine was not shut down or turned off prior to the employee engaging in this servicing activity, thereby exposing them to struck-by and crushing hazards from the unexpected movement of the machine. As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Translate