Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1628851.015
Citation: 01002
Citation Type: Serious
Abatement Status: Not Completed - AD Discretion
Initial Penalty: $10,046.00
Current Penalty: $5,023.00
Issuance Date: 04/18/2023
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 02/05/2025
Gravity: 5
Report ID: 0627100
Contest Date: 04/25/2023
Final Order: 01/15/2025
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 01/15/2025 | $5,023.00 | 02/05/2025 | Serious | |
Penalty | C: Contested | 04/25/2023 | $10,046.00 | 05/12/2023 | Serious | |
Penalty | Z: Issued | 04/18/2023 | $10,046.00 | 05/12/2023 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: On or about October 18, 2022, at the mixer's drive motor, employees engaged in work activities related to block manufacturing were exposed to the rotating shaft from the mixer to the gear reduction box that was not enclosed.