Violation Detail
Standard Cited: 19100212 A05 General requirements for all machines.
Inspection Nr: 1620265.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $6,215.00
Current Penalty: $3,100.00
Issuance Date: 12/16/2022
Nr Instances: 2
Nr Exposed: 3
Abatement Date:
Gravity: 1
Report ID: 0524500
Contest Date:
Final Order: 01/11/2023
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/11/2023 | $3,100.00 | Serious | ||
| Penalty | Z: Issued | 12/16/2022 | $6,215.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch: On or about September 7, 2022, employees working in the Hot House room were exposed to injury from contact with fan blades: a. Employees using the 8-inch Shaefer Versa-Kool fan resting on the floor next to the work table and the front guards were approximately 1-inch wide. b. Employees using the 8-inch Shaefer Versa-Kool fan resting on the bottom shelf next to the work table and the front guards were approximately 1-inch wide.
Translate