Violation Detail
Standard Cited: 19100101 B Compressed gases (general requirements).
Inspection Nr: 1613555.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,801.00
Current Penalty: $4,185.00
Issuance Date: 12/28/2022
Nr Instances: 2
Nr Exposed: 10
Abatement Date: 01/25/2023
Gravity: 5
Report ID: 0213900
Contest Date:
Final Order: 01/19/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/19/2023 | $4,185.00 | 01/25/2023 | Serious | |
Penalty | Z: Issued | 12/28/2022 | $5,801.00 | 01/25/2023 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.101(b):The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: a) Shop Bays/Welding Bay 1: On or about 8/9/2022, four compressed gas cylinders were not secured while being stored against the wall near the roll-up door. b) Shop Bays/Welding Bay 2: On or about 8/9/2022, two compressed gas cylinders were not secured while being stored against the wall in front of the electrical panel. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.