Violation Detail
Standard Cited: 19100107 C06 Spray finishing using flammable and combustible materials.
Inspection Nr: 1607792.015
Citation: 01002
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $13,674.00
Current Penalty: $0.00
Issuance Date: 09/26/2022
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 03/15/2024
Gravity: 5
Report ID: 0522500
Contest Date: 10/24/2022
Final Order: 11/16/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 11/16/2023 | $0.00 | 03/15/2024 | Other | |
Penalty | C: Contested | 11/07/2022 | $13,674.00 | 10/31/2022 | Serious | |
Penalty | Z: Issued | 09/26/2022 | $13,674.00 | 10/31/2022 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.107(c)(6): Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations. a. On or about August 13, 2022, in the Cover Department, the electrical equipment used in the lid/cover lining spray booth was not explosion proof. b. On or about August 13, 2022, in the Cover Department, the electrical equipment used in the exterior lid/cover spray booth was not explosion proof.