Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1607618.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,052.00
Current Penalty: $6,526.00
Issuance Date: 12/09/2022
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 12/29/2022
Gravity: 10
Report ID: 0523400
Contest Date:
Final Order: 12/27/2022
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/27/2022 | $6,526.00 | 12/29/2022 | Serious | |
| Penalty | Z: Issued | 12/09/2022 | $13,052.00 | 12/29/2022 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(7)(i):The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: (a) On or about July 13, 2022, employees performing maintenance and servicing on the Schelling cut-to-size saw, were not adequately trained to recognize the types of energy sources associated with the equipment, and how to implement energy isolating methods to prevent the inadvertent release or start-up of equipment being worked on.
Translate