Violation Detail
Standard Cited: 19100147 F01 II The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1585238.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $14,502.00
Current Penalty: $0.00
Issuance Date: 08/05/2022
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 08/31/2022
Gravity: 10
Report ID: 0729700
Contest Date: 08/26/2022
Final Order: 02/10/2023
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 02/10/2023 | $0.00 | 08/31/2022 | Serious | |
Penalty | C: Contested | 08/26/2022 | $14,502.00 | 08/31/2022 | Serious | |
Penalty | Z: Issued | 08/05/2022 | $14,502.00 | 08/31/2022 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(f)(1)(ii):When lockout or tagout devices temporarily were removed from the energy isolating device and the machine or equipment was energized to test or position the machine, the employees were not removed from the machine or equipment area in accordance to paragraph (e)(2): In the Formation Area, employee(s) were exposed to amputation and electric shock hazards in that an energy isolation device was removed from a machine during maintenance activities. The machine was energized to test the position of replacement parts, and the employee was not removed from the machine which resulted in an employee amputation.