Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1578518.015
Citation: 01002
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $10,566.00
Current Penalty: $6,339.60
Issuance Date: 04/15/2022
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC): R
Gravity: 5
Report ID: 0419400
Contest Date:
Final Order: 05/10/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/10/2022 | $6,339.60 | Serious | ||
Penalty | Z: Issued | 04/15/2022 | $10,566.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: (a) No. 1 Blow Fill - On or about February 15, 2022 the employer did not guard a rotating shaft exposing employees to a caught-in hazard.