Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1578381.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,052.00
Current Penalty: $13,052.00
Issuance Date: 05/19/2022
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 05/31/2022
Gravity: 10
Report ID: 0522500
Contest Date:
Final Order: 06/15/2022
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 05/19/2022 | $13,052.00 | 05/31/2022 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(4)(ii):The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: 29 CFR 1910.147(c)(4)(ii)(B): Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy; a. On or about February 22, 2022, the employer failed to maintain a lockout/tagout (LOTO) program that gave specific procedural steps for shutting down, isolating, blocking, and securing the mobile four-inch pump to control hazardous energy. This LOTO failure resulted in an employee been hospitalized due to burns to the upper torso and arms.