Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 1558590.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $10,360.00
Current Penalty: $7,770.00
Issuance Date: 04/05/2022
Nr Instances: 2
Nr Exposed: 7
Abatement Date:
Gravity: 5
Report ID: 0627100
Contest Date:
Final Order: 05/02/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/02/2022 | $7,770.00 | Serious | ||
Penalty | Z: Issued | 04/05/2022 | $10,360.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: The employer did not ensure that projecting and rotating shaft ends on two Blower Machines in the Workshop department were guarded with non-rotating cap or safety sleeve: a) On each side of Blower Machine #1, rotating shaft ends approximately 1.3-inch in diameter that projected approximately 3.2-inches, were not guarded. b) On each side of Blower Machine #4, rotating shaft ends approximately 1.4-inch in diameter that projected approximately 2.8-inches, were not guarded.