Violation Detail
Standard Cited: 19261053 B01 Ladders.
Inspection Nr: 1556628.015
Citation: 01002
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $2,486.00
Current Penalty: $1,491.60
Issuance Date: 02/03/2022
Nr Instances: 1
Nr Exposed: 8
Related Event Code (REC):
Gravity: 5
Report ID: 0729300
Contest Date:
Final Order: 03/08/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/08/2022 | $1,491.60 | Serious | ||
Penalty | Z: Issued | 02/03/2022 | $2,486.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access: On 10/4/2021, employees of HR Vasquez Construction LLC were performing roofing work at 1006 Regency Manor Drive, Ballwin, Missouri. An extension ladder was placed on the West side of the house and used to access the upper landing surface of the roof. The side rails of the ladder did not extended 3 feet above the upper surface.