Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1549895.015
Citation: 01002
Citation Type: Serious
Abatement Status:
Initial Penalty: $7,510.00
Current Penalty: $0.00
Issuance Date: 09/30/2021
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 10/20/2021
Gravity: 5
Report ID: 0522300
Contest Date:
Final Order: 10/21/2021
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/21/2021 | $0.00 | 10/20/2021 | Serious | |
| Penalty | Z: Issued | 09/30/2021 | $7,510.00 | 10/20/2021 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(4)(ii)(B): Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy had not been put into place. On or about August 26, 2021 the employer failed to ensure that all specific procedural steps were contained in the machine specific procedures of the P.M. Wire Drawing Machine. The employer failed to include steps for ensuring that rotating coil blocks had come to a complete stop before proceeding with the remainder of the LO/TO procedural steps.