Violation Detail
Standard Cited: 19260405 G02 IV Wiring methods, components, and equipment for general use.
Inspection Nr: 1539140.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $5,461.00
Current Penalty: $3,300.00
Issuance Date: 12/22/2021
Nr Instances: 1
Nr Exposed: 9
Abatement Date:
Gravity: 5
Report ID: 0215000
Contest Date:
Final Order: 01/19/2022
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/19/2022 | $3,300.00 | Serious | ||
| Penalty | Z: Issued | 12/22/2021 | $5,461.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.405(g)(2)(iv):Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: Location: 571 Ocean Parkway, Brooklyn, NY 11218 On or about: June 30, 2021 (a) The employer did not ensure that strain relief was provided to flexible cords energizing a rebar bender; the flexible cords had strain damage exposing the internal wire insulation.