Violation Detail
Standard Cited: 19260651 C02 Specific Excavation Requirements.
Inspection Nr: 1523626.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $7,461.00
Current Penalty: $7,461.00
Issuance Date: 09/10/2021
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 5
Report ID: 0523400
Contest Date: 10/05/2021
Final Order: 10/28/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 10/28/2022 | $7,461.00 | Serious | ||
Penalty | C: Contested | 10/05/2021 | $7,461.00 | Serious | ||
Penalty | Z: Issued | 09/10/2021 | $7,461.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: (a) On or about April 6, 2021, at a job site located West of Sentry Drive on West Sunset Drive, Waukesha, WI, employees were working in a trench approximately Fifteen (15) feet deep and approximately one hundred (100) feet in length without a means of egress installed to require no more than 25 feet of lateral travel to an egress point.