Violation Detail
Standard Cited: 19100146 D01 Permit-required confined spaces
Inspection Nr: 1521125.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $12,288.00
Current Penalty: $4,634.52
Issuance Date: 08/18/2021
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 10
Report ID: 0729300
Contest Date:
Final Order: 10/01/2021
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/01/2021 | $4,634.52 | Serious | ||
| Penalty | Z: Issued | 08/18/2021 | $12,288.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.146(d)(1):Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not implement the measures necessary to prevent unauthorized entry: a) At 123 Byassee Drive, Hazelwood, MO 63042 - On or about March 21, 2021, Cabka North America, Inc. had not implemented the necessary measures to prevent unauthorized entry by employee(s) assigned material handling duties at Bunker 1-5 on the Production Floor.
Translate