Violation Detail
Standard Cited: 19260651 C02 Specific Excavation Requirements.
Inspection Nr: 1516973.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $12,288.00
Current Penalty: $8,601.60
Issuance Date: 08/20/2021
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 10
Report ID: 0317300
Contest Date:
Final Order: 09/14/2021
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/14/2021 | $8,601.60 | Serious | ||
Penalty | Z: Issued | 08/20/2021 | $12,288.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) Southwest of intersection of Delaware Route 20 and Sheep Pen Road, Millsboro, DE 19966: On or about 02/26/2021; the employer failed to ensure a ladder or other safe means of egress was available in the trench that was approximately 12 feet deep and 30 feet long. The trench had a ladder for egress but it was removed for another project at the site and a ramp was put in. The excavator (being operated by the competent person) was filling in the ramp with 3 employees still in the trench working.