Violation Detail
Standard Cited: 19261053 A15 Ladders.
Inspection Nr: 1513556.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,096.00
Current Penalty: $2,450.00
Issuance Date: 07/22/2021
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 10
Report ID: 0317500
Contest Date:
Final Order: 08/06/2021
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/06/2021 | $2,450.00 | Serious | ||
| Penalty | Z: Issued | 07/22/2021 | $4,096.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.1053(a)(15):The minimum perpendicular clearance between the centerline of fixed ladder rungs, cleats, and steps, and the unavoidable obstruction on the climbing side of the ladder was less than 24 inches (61 cm): (a) Jobsite: On or about February 2, 2021, employees were using the fixed ladder from the 8th floor exterior fire escape to access the roof and the bottom of this ladder (bottom 3 rungs) was within 24 inches of the exterior fire escape platform railing.