Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1505481.015
Citation: 01002
Citation Type: Serious
Abatement Date: 06/25/2021 2
Initial Penalty: $10,728.00
Current Penalty: $15,625.00
Issuance Date: 06/03/2021
Nr Instances: 1
Nr Exposed: 6
Related Event Code (REC):
Gravity: 5
Report ID: 0523300
Contest Date: 06/23/2021
Final Order: 04/15/2024
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 04/15/2024 | $15,625.00 | 06/25/2021 | Serious | |
Penalty | C: Contested | 06/28/2021 | $10,728.00 | 06/25/2021 | Serious | |
Penalty | Z: Issued | 06/03/2021 | $10,728.00 | 06/25/2021 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures shall clearly and specifically outline the specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: (a) On or about March 1, 2021, the energy control procedures for bucket elevator legs did not specifically outline the steps for isolating, blocking, and securing the leg belt from movement due to gravity during the clearing of plugged elevator legs.