Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1502017.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,011.00
Current Penalty: $9,011.00
Issuance Date: 05/07/2021
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 06/24/2021
Gravity: 5
Report ID: 0418200
Contest Date: 05/20/2021
Final Order: 03/04/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 03/04/2022 | $9,011.00 | 06/24/2021 | Serious | |
Penalty | C: Contested | 08/16/2021 | $9,011.00 | 06/24/2021 | Serious | |
Penalty | Z: Issued | 05/07/2021 | $9,011.00 | 06/24/2021 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: On or about 11/09/2020, the company's lockout/tag out procedure did not include specific procedural steps or additional methods and instructions for the control of potentially hazardous energy sources when servicing/performing maintenance activities on machinery such as, but not limited to; 12 foot (Accupress Model 717512, serial # 9972, the 16 foot (Accupress Model 717512, serial # 7214) Press Brakes, the and CNC Laser (FANUC Laser C2000 Type A04B-0813-B341, S/N: L12x20765). Energy sources used at facility include, but are not limited to, electrical, pneumatic and hydraulic energy.