Violation Detail
Standard Cited: 19100134 F02 Respiratory Protection.
This violation item has been deleted.
Inspection Nr: 1501977.015
Citation: 01002
Citation Type: Serious
Abatement Status:
Initial Penalty: $8,192.00
Current Penalty: $0.00
Issuance Date: 05/10/2021
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 06/16/2021
Gravity: 5
Report ID: 0521400
Contest Date: 05/12/2021
Final Order: 11/17/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 11/17/2022 | $0.00 | 06/16/2021 | Serious | |
Penalty | C: Contested | 05/17/2021 | $8,192.00 | 06/16/2021 | Serious | |
Penalty | Z: Issued | 05/10/2021 | $8,192.00 | 06/16/2021 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) was used, and at least annually thereafter: On or about November 11, 2020, employees were exposed to respiratory stressors associated with being required to wear N95 filtering facepieces while manufacturing a water-activated product used to generate chlorine dioxide and the employer did not ensure that employees were fit tested prior to requiring them to wear the respirator. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).