Violation Detail
Standard Cited: 19100147 F03 II D The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1493526.015
Citation: 01002
Citation Type: Serious
Abatement Status:
Initial Penalty: $13,653.00
Current Penalty: $0.00
Issuance Date: 03/16/2021
Nr Instances: 4
Nr Exposed: 6
Abatement Date: 04/02/2021
Gravity: 10
Report ID: 0625700
Contest Date: 04/07/2021
Final Order: 01/04/2023
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection | 
|---|---|---|---|---|---|---|
| Penalty | R: Review Commission | 01/04/2023 | $0.00 | 04/02/2021 | Serious | |
| Penalty | C: Contested | 05/05/2021 | $13,653.00 | 04/02/2021 | Serious | |
| Penalty | Z: Issued | 03/16/2021 | $13,653.00 | 04/02/2021 | Serious | 
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(f)(3)(ii)(D): A personal lockout or tagout device(s) was not affixed to the group lockout device, group lockbox or comparable mechanism when he or she began work (and to be removed when work stops) on the machine or equipment serviced and/ or maintained. (a) On or about September 17, 2020, at the #5 Crude unit of the Calcasieu Refinery facility, crewmembers failed to affix a personal lock to the group lockbox before vacuuming leaking crude oil from the heater (H-501) convection section.