Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1483730.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,639.00
Current Penalty: $9,639.00
Issuance Date: 08/12/2020
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 08/26/2020
Gravity: 5
Report ID: 0521400
Contest Date:
Final Order: 09/09/2020
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 08/12/2020 | $9,639.00 | 08/26/2020 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about June 25, 2020, the employer failed to document and utilize hazardous energy (lockout / tagout) control procedures for the Gallard Henning Nopak Baler. This exposed employees who cleared jams from the equipment to caught-in hazards that could result in serious injury. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).