Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1482240.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $10,390.00
Current Penalty: $7,000.00
Issuance Date: 12/28/2020
Nr Instances: 2
Nr Exposed: 3
Abatement Date: 07/22/2022
Gravity: 10
Report ID: 0522000
Contest Date: 01/22/2021
Final Order: 06/22/2022
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 06/22/2022 | $7,000.00 | 07/22/2022 | Serious | |
Penalty | C: Contested | 01/26/2021 | $10,390.00 | 02/16/2021 | Serious | |
Penalty | Z: Issued | 12/28/2020 | $10,390.00 | 02/16/2021 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section. a) On or about July 7, 2020, the employer had not utilized a hazardous energy control procedure with all of the required elements for equipment such as but not limited to the Giddings & Lewis Horizontal Boring Mill Model H70FX SN#465-11 when repairing the equipment. b) On or about August 18, 2020, the employer had not utilized a hazardous energy control procedure with all of the required elements for equipment such as but not limited to the Toshiba TUE-200 Vertical Lathe SN 440588 which requires manual tool changes be performed by the operator.