Violation Detail
Standard Cited: 19100212 B General requirements for all machines.
Inspection Nr: 1452724.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,048.00
Current Penalty: $2,024.00
Issuance Date: 04/06/2020
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 1
Report ID: 0214200
Contest Date:
Final Order: 04/23/2020
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/23/2020 | $2,024.00 | Serious | ||
| Penalty | Z: Issued | 04/06/2020 | $4,048.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a) Establishment/production shop The machine, such as, but not limited to, Clausing milling machine, that was designed for a fixed location was not securely anchored to the floor to prevent moving. Violation occurred on or about 12/20/2019.