Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1445016.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,193.00
Current Penalty: $5,000.00
Issuance Date: 02/12/2020
Nr Instances: 1
Nr Exposed: 15
Abatement Date: 03/03/2020
Gravity: 5
Report ID: 0523400
Contest Date:
Final Order: 03/09/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/09/2020 | $5,000.00 | 03/03/2020 | Serious | |
| Penalty | Z: Issued | 02/12/2020 | $8,193.00 | 03/03/2020 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(d)(2): An orderly shutdown of machine or equipment was not utilized to avoid any additional or increased hazards to employees as a result of equipment stoppage: (a) On or about November 8, 2019, the employer did not ensure the Coin Sorter was properly shut down utilizing a hazardous energy control program procedure (Lockout/Tagout), which exposed employees to caught-in and crushing hazards and amputation injury.