Violation Detail
Standard Cited: 19260451 E01 General requirements.
Inspection Nr: 1442331.015
Citation: 01002
Citation Type: Serious
Abatement Status: Not Completed - Worksite Changed
Initial Penalty: $4,048.00
Current Penalty: $2,024.00
Issuance Date: 03/30/2020
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 05/14/2020
Gravity: 10
Report ID: 0420600
Contest Date:
Final Order: 04/10/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/10/2020 | $2,024.00 | 05/14/2020 | Serious | |
Penalty | Z: Issued | 03/30/2020 | $4,048.00 | 05/14/2020 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a. At the site located at 126290 S HWY 27 Clermont, FL, building C, employees were exposed to fall hazards when climbing on and off a scaffold using the scaffold frame and cross braces, on or about October 30, 2019.